5012C-E46TAG

Electric Power Generation 5012C-E46TAG

Request Consultation Find your Distributor

Key Specs

Gross Mechanical Output
1252-1645 kW
1252-1645 kW
Typical Electrical Output
1408-1876 kVA (1127-1501 kWe)
1408-1876 kVA (1127-1501 kWe)
Emissions
U.S. EPA Stationary Emergency Engine emits equivalent to Tier 2
U.S. EPA Stationary Emergency Engine emits equivalent to Tier 2

Tools And Expert Help At Every Turn

Overview

The Perkins® 5012C-E46TAG has been designed to offer reliable power for the emergency standby and critical applications market, including data centres and hospitals among others.

Engineered and built specifically for the power generation market, the Perkins® 5000 Series is a power-packed engine range built to be dependable, versatile and offer lower emissions to meet regulatory standards.

Features At A Glance

Displaying 1-6 of 4

Perkins

Maximised productivity

The 5000 Series delivers maximised productivity through outstanding load acceptance, achieving NFPA110 Type 10 and ISO 8528-5 G2 and G3 performance class and delivers high altitude capability. The engine build and performance have been designed with ultimate productivity and dependability in mind, so customers can be confident that power will be available when required.



Perkins

Ease of integration and service accessibility

A single point customer electronics connection supports ease of integration and service accessibility is provided from a single side with two year oil and fuel service intervals.
Perkins

Low daily operating costs

Excellent oil consumption through dedicated piston, ring and liner assembly and low fuel consumption deliver minimised daily operating costs.
Perkins

Advanced technology

The 5000 Series utilises advanced technology, with full authority electronics, that easily integrate into the customer's chosen telematic solutions. We offer an optional closed crankcase ventilation system to reduce crankcase emissions further, if required.

Product Specifications for 5012C-E46TAG

Gross Mechanical Output 1252-1645 kW 1252-1645 kW
Typical Electrical Output 1408-1876 kVA (1127-1501 kWe) 1408-1876 kVA (1127-1501 kWe)
Rated Speed 1800 rpm 1800 rpm
Emissions U.S. EPA Stationary Emergency Engine emits equivalent to Tier 2 U.S. EPA Stationary Emergency Engine emits equivalent to Tier 2
Prime 1408-1688 kVA (1127-1351 kWe) 1408-1688 kVA (1127-1351 kWe)
Standby 1563-1876 kVA (1250-1501 kWe) 1563-1876 kVA (1250-1501 kWe)
Number of Cylinders 12 Vee 12 Vee
Displacement 2797.3 in³ 45.84 l
Aspiration Turbocharged and air-to-air chargecooled Turbocharged and air-to-air chargecooled
Bore 6.3 in 160 mm
Stroke 7.5 in 190 mm
Combustion System Direct injection Direct injection
Compression Ratio 13.8:1 13.8:1
Aftertreatment None None
Total Lubricating Oil Capacity 41.61 gal (US) 157.5 l
Total Coolant Capacity 58.38 gal (US) 221 l
Rotation from Flywheel End Anti-clockwise Anti-clockwise
Cooling System Liquid Liquid
Typical Alternator Efficiency 95% 95%
Switchable No No
Length 163.1 in 4143 mm
Width 86.6 in 2200 mm
Height 89.5 in 2273 mm
Dry Weight 12919 lb 5860 kg
Wet Weight 13735 lb 6230 kg
Note 1 *Generator powers are typical and based on typical alternator efficiencies and a power factor (cos θ) or 0.8 *Generator powers are typical and based on typical alternator efficiencies and a power factor (cos θ) or 0.8
Note 2 *Final dimensions dependent on selected options *Final dimensions dependent on selected options
Emergency standby power (ESP) Limited to 200 hours usage per year with an average load factor of 80 percent of the published ESP rating over each 24 hour period. Limited to 200 hours usage per year with an average load factor of 80 percent of the published ESP rating over each 24 hour period.
Data centre power (DCP) Power available for variable or continuous electrical loads in a data centre application. Up to 100 percent load factor of the published DCP power is permitted for unlimited time. An overload of 10 percent is permitted for one hour in every 12 hours of operation. No overload is permitted. DCP power definition relies on ISO8528-1 2018 standard to be followed by generator set manufacturer, and will support Tier I to Tier IV classifications of data centres as per UPTIME institute guidelines. Power available for variable or continuous electrical loads in a data centre application. Up to 100 percent load factor of the published DCP power is permitted for unlimited time. An overload of 10 percent is permitted for one hour in every 12 hours of operation. No overload is permitted. DCP power definition relies on ISO8528-1 2018 standard to be followed by generator set manufacturer, and will support Tier I to Tier IV classifications of data centres as per UPTIME institute guidelines.

5012C-E46TAG Standard Equipment

Electro Unit or ElectropaK

  • ElectropaK

Radiator fitted

  • Yes

Fuel filter, engine mounted

  • Yes

Water separator

  • Optional

Fuel water sight glass

  • Yes

Fuel priming pump (manual/electric)

  • Electric

WIF sensor

  • Yes

Fuel cooler

  • Yes

Air filter, engine mounted

  • Yes

Engine ECM, engine mounted

  • Yes

Wiring harness to ECM

  • Yes

Wiring harness (all connectors to single customer interface)

  • Yes

Starter motor

  • Yes

Battery charging alternator

  • Yes

Flywheel housing

  • Yes

Flywheel

  • 18"/21"

Fan

  • Yes

Fan guard

  • Yes

Temperature and oil pressure for automatic stop/alarm configurable

  • Yes

See how 5012C-E46TAG compares against frequently compared products.

Use the comparison tool to compare detailed specs of Perkins and competitor models.

Compare All Models