5006A-E23TAG

Electric Power Generation 5006A-E23TAG

Request Consultation Find your Distributor

Key Specs

Gross Mechanical Output
533-788 kW
533-788 kW
Typical Electrical Output
600-900 kVA (480-720 kWe)
600-900 kVA (480-720 kWe)
Emissions
Fuel Optimised
Fuel Optimised

Tools And Expert Help At Every Turn

Overview

The Perkins® 5006A-E23TAG has been designed to offer reliable power for all electric power applications, including standby, prime, critical and data centres.

Engineered and built specifically for the power generation market, the Perkins® 5000 Series is a power-packed engine range built to be dependable, versatile and offer low daily operating costs.

Features At A Glance

Displaying 1-6 of 4

Perkins

Maximised productivity

The 5000 Series delivers maximised productivity through outstanding load acceptance, achieving NFPA110 Type 10 and ISO 8528-5 G2 and G3 performance class and deliver high altitude capability.

The engine build and performance have been designed from the ground up with ultimate productivity and dependability in mind, so customers can be confident that power will be available when required.

They have been tested around the world, in the harshest environments, to deliver performance, no matter the conditions.
Perkins

Minimised daily operating costs

Excellent oil consumption through dedicated piston, ring and liner assembly and low fuel consumption deliver minimised daily operating costs.
Perkins

Ease of integration and service accessibility

Design of core engine components mean the 5000 Series delivers more power, more quickly no matter the demands of the application or the environment in which it is placed.

A single point customer electronics connection supports ease of integration and service accessibility is provided from a single side with 500 hours or two year oil and fuel service interval whichever comes first.
Perkins

Advanced technology

The 5000 Series utilises advanced technology, with full authority electronics, that easily integrate into the customer’s chosen telematic solutions and is optimised for efficiency in fuel consumption.

Product Specifications for 5006A-E23TAG

Gross Mechanical Output 533-788 kW 533-788 kW
Typical Electrical Output 600-900 kVA (480-720 kWe) 600-900 kVA (480-720 kWe)
Rated Speed 1500 rpm 1500 rpm
Emissions Fuel Optimised Fuel Optimised
Prime 750-800 kVA (600-640 kWe) 750-800 kVA (600-640 kWe)
Standby 825-900 KVA (660-720 kWe) 825-900 KVA (660-720 kWe)
Baseload 600-640 kVA (480-512 kWe) 600-640 kVA (480-512 kWe)
Number of Cylinders 6 6
Bore 6.3 in 160 mm
Stroke 7.5 in 190 mm
Displacement 1398.73 in³ 22.921 l
Compression Ratio 13.8:1 13.8:1
Aspiration Turbocharged and air-to-air chargecooled Turbocharged and air-to-air chargecooled
Combustion System Direct injection Direct injection
Rotation from Flywheel End Anti-clockwise Anti-clockwise
Cooling System Watercooled Watercooled
Aftertreatment N/A N/A
Typical Alternator Efficiency 94% 94%
Switchable No No
Length 107.4 in 2730 mm
Width 66.5 in 1690 mm
Height 83.7 in 2126 mm
Dry Weight 6195 lb 2810 kg
Length 89.6 in 2276 mm
Width 56.9 in 1446 mm
Height 68.7 in 1745 mm
Dry Weight 5303 lb 2405 kg
Note 1 *Final dimensions dependent on selected options *Final dimensions dependent on selected options
Prime Power Unlimited hours usage with an average load factor of 80 percent of the published prime power over each 24 hour period. A 10 percent overload is available for one hour in every 12 hours operation. Unlimited hours usage with an average load factor of 80 percent of the published prime power over each 24 hour period. A 10 percent overload is available for one hour in every 12 hours operation.
Standby Power Limited to 500 hours usage with an average load factor of 80 percent of the published standby power rating over each 24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted. Limited to 500 hours usage with an average load factor of 80 percent of the published standby power rating over each 24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted.
Baseload Unlimited hours usage with an average load factor of 100 percent of the published continuous operating power. No overload is permitted on continuous operating power. Unlimited hours usage with an average load factor of 100 percent of the published continuous operating power. No overload is permitted on continuous operating power.

5006A-E23TAG Standard Equipment

Electro unit or ElectropaK

  • Both

Radiator fitted

  • Loose

Fuel filter

  • Engine mounted

Water separator

  • N/A

Fuel priming pump (manual/electric)

  • Electric

Fuel cooler

  • Not required for most installations

Air filter

  • Engine mounted

Engine ECM

  • Engine mounted

Wiring harness

  • To ECM
  • All connectors to single customer interface

Temperature and oil pressure for automatic stop/alarm

  • Configurable

See how 5006A-E23TAG compares against frequently compared products.

Use the comparison tool to compare detailed specs of Perkins and competitor models.

Compare All Models

Check out current offers for the 5006A-E23TAG